Korean Journal of Veterinary Research 1992;32(3):421-427.
Evaluation of erythrocyte sedimentation rate in racehorse measured by westergren method
Byoung-jin Kim1, Bang-whan Lee2, Chai-yong Lee2
1Korean Horse Affairs Association
2College of Veterinary Medicine, Chonnam National University
경주마(競走馬)에서 Westergren법(法)에 의한 적혈구 침강속도(沈降速度) 측정의 평가(評價)
김병진1, 이방환2, 이채용2
1한국마사회
2전남대학교 수의과대학
Abstract
The study was basically carried out to establish the appropriate condition for applying the Westergren method for erythrocyte sedimentation rate(W-ESR) in Throughbred racehorses at recess. To do this, we examined the correlationship among some factors including the kind of anticoagulants, optimal ambient temperature and reading time for W-ESR in healthy racehorses. The difference between the blood samples treated with only 3.8% solution of sodium citrate(SC) and both EDTA and SC as a coagulant, there was not recognized any significant difference(p<0.05) in the levels of W-ESR irrespective of the ambient temperature of $20^{circ}C$ or $30^{circ}C$. The best optimal ambient temperature for W-ESR in horses was proved at $30^{circ}C$ resulting from the tendency of the most reduced dispersion in mean values analyaed from repeatly 4 times to the same blood samles compared with those of $10^{circ}C$ and $20^{circ}C$. The optimal reading time was determined as 60 minutes(Y=237.2~4.1X, $r^2=0.998$) and 70 minutes(Y=247.8~4.2X, $r^2=0.999$) under the same temperature of $30^{circ}C$; the latter showed the better result on the basis of the correlation of packed cell volume(PCV) and ESR values. About 13 healthy racehorses, we compared the real values of W-ESR respectively obtained at 60 minutes and 70 minutes at $30^{circ}C$ with the anticipated values of PCV by means of the analysis of linear regression equitation. As the result of this, the strong correlation between both of them was confirmed. For practical use of W-ESR in Thoroughbred racehorese, we can recommend the condition of 60 or 70 minutes for the optimal reading time as well as $30^{circ}C$ for the best ambient temperature.
Key Words: erythrocyte sedimentation rate(ESR), Westergren-ESR, ambient temperature, racehorse, reading time
TOOLS
METRICS Graph View
  • 420 View
  • 1 Download
Related articles


About
Browse articles
For contributors
Policy
Editorial Office
#401-1, 85 Bldg., College of Veterinary Medicine, Seoul National University
1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea
Tel: +82-2-880-1229    Fax: +82-2-878-9762    E-mail: jvs@ksvs.or.kr                

Copyright © 2024 by The Korean Society of Veterinary Science.

Developed in M2PI

Close layer
prev next